Sign In | Join Free | My burrillandco.com
Home > ABB Spare Parts >

RDCU-02C 64607901 ABB Relion® 650/670 series protection devices distributed communication control units

Xiamen Changxuyuan Trading Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap RDCU-02C 64607901 ABB Relion® 650/670 series protection devices distributed communication control units from wholesalers
     
    Buy cheap RDCU-02C 64607901 ABB Relion® 650/670 series protection devices distributed communication control units from wholesalers
    • Buy cheap RDCU-02C 64607901 ABB Relion® 650/670 series protection devices distributed communication control units from wholesalers
    • Buy cheap RDCU-02C 64607901 ABB Relion® 650/670 series protection devices distributed communication control units from wholesalers
    • Buy cheap RDCU-02C 64607901 ABB Relion® 650/670 series protection devices distributed communication control units from wholesalers
    • Buy cheap RDCU-02C 64607901 ABB Relion® 650/670 series protection devices distributed communication control units from wholesalers

    RDCU-02C 64607901 ABB Relion® 650/670 series protection devices distributed communication control units

    Ask Lasest Price
    Brand Name : ABB
    Model Number : RDCU-02C
    Certification : COO & COC
    Price : $111-$123
    Payment Terms : T/T,paypal,alipay
    Supply Ability : 99+
    Delivery Time : 3-5 days
    • Product Details
    • Company Profile

    RDCU-02C 64607901 ABB Relion® 650/670 series protection devices distributed communication control units

    RDCU-02C 64607901 ABB Relion® 650/670 series protection devices distributed communication control units


    Product Overview

    ABB RDCU-02C is a Distributed communication and control unit (Remote Distributed) specifically designed for Relion® 650 and 670 series multi-functional protection relays (such as REF650, REM650, REB650, RED670, etc.) (Communication Unit). As an intelligent expansion node of the main protection device, RDCU-02C not only provides additional digital input/output (DI/DO) channels, but also supports IEC 61850 GOOSE communication, achieving high-speed interlocking, state sharing and distributed automation logic.


    Core features

    Flexible I/O expansion
    16-channel programmable digital input (DI) : Supports dry contacts or wet contacts (24-250 V DC/AC)
    8-channel programmable relay output (DO) : single-pole double-throw (SPDT) contacts, 5 A @ 250 V AC
    High-speed communication interface
    2 × Fiber optic ST interface: Supports IEC 61850-9-2 LE/GOOSE (rate 100 Mbps)
    1 × RS-485 interface: For local debugging or Modbus RTU (optional)
    Plug-and-play configuration: Automatically recognized through the PCM600 engineering tool, supporting online parameter download
    High anti-interference and isolation:
    The electrical isolation between input and output is ≥ 5 kV
    It complies with strict EMC standards such as IEC 61000-4-5 (Surge) and IEC 61000-4-5 (EFT)
    LED status indication: Power supply, operation, communication, fault, and the status of each DI/DO channel are clearly visible
    Wide temperature design: Suitable for extreme industrial environments ranging from -40°C to +70°C


    Technical parameters

    Digital substation: As a GOOSE network terminal, it realizes the interlocking of circuit breaker failure and busbar protection
    Large motor group control: Centralized collection of the status of multiple motors, remote start and stop, and feedback of operation signals
    Distributed energy access: Achieving coordinated control of inverters and disconnectors in photovoltaic/wind farms
    Industrial distribution network automation: Building a "hardwired" interlocking logic to reduce construction and maintenance costs
    Renovation project: On the basis of retaining the original protective devices, rapidly upgrade to the IEC 61850 architecture


    Installation and Usage instructions
    Mechanical installation
    Installed on the DIN rail inside the target switch cabinet, close to the monitored equipment;
    The panel can be fixed using the included bracket.
    Electrical and communication connections
    Connect the RDCU interface of the main relay through a dedicated 12-core shielded cable;
    The optical fiber is connected to the station-level Process Bus switch.
    The on-site signal lines are connected to the terminal block (DI: 1-32; DO: 33-48).
    Software configuration
    Guide the main relay configuration in the PCM600 engineering tool;
    Automatically identify RDCU-02C and allocate DI/DO logic functions;
    Configure the GOOSE publish/subscribe dataset (such as "Circuit breaker Position → Busbar differential protection").
    Debugging and verification
    Monitor the I/O status online through the front panel LED or PCM600.
    Verify the correctness of the GOOSE message using the IEC 61850 SCL file.


    Product Images



    Related Products


    RDCU-01CRDCU-02C
    RDCU-03CRDCU-04C
    RDCU-05CRDCU-06C
    RDCU-07CRDCU-08C
    RDCU-09CRDCU-10C
    AFIN-01CAFIN-02C
    FENA-01FENA-11
    FENA-21FENA-31
    NPBA-12FPBA-01
    NDSC-01PSMU-40C


    Quality RDCU-02C 64607901 ABB Relion® 650/670 series protection devices distributed communication control units for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xiamen Changxuyuan Trading Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)