Sign In | Join Free | My burrillandco.com
Home > ABB Spare Parts >

SPAU 140 C ABB Synchro-check Relay Voltage-check Relay 50Hz 250V Ac/dc

Xiamen Changxuyuan Trading Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap SPAU 140 C ABB Synchro-check Relay Voltage-check Relay 50Hz 250V Ac/dc from wholesalers
     
    Buy cheap SPAU 140 C ABB Synchro-check Relay Voltage-check Relay 50Hz 250V Ac/dc from wholesalers
    • Buy cheap SPAU 140 C ABB Synchro-check Relay Voltage-check Relay 50Hz 250V Ac/dc from wholesalers
    • Buy cheap SPAU 140 C ABB Synchro-check Relay Voltage-check Relay 50Hz 250V Ac/dc from wholesalers
    • Buy cheap SPAU 140 C ABB Synchro-check Relay Voltage-check Relay 50Hz 250V Ac/dc from wholesalers

    SPAU 140 C ABB Synchro-check Relay Voltage-check Relay 50Hz 250V Ac/dc

    Ask Lasest Price
    Brand Name : ABB
    Model Number : SPAU 140 C
    Certification : COO & COC
    Price : $300-$400
    Payment Terms : T/T,paypal,alipay
    Supply Ability : 99+
    Delivery Time : 3-5 days
    • Product Details
    • Company Profile

    SPAU 140 C ABB Synchro-check Relay Voltage-check Relay 50Hz 250V Ac/dc

    SPAU 140 C ABB Synchro-check Relay Voltage-check Relay 50Hz 250V Ac/dc


    I. Key Functions
    1. Synchronization Check – When both sides of the network are energized, the circuit breaker can only be closed if the voltage difference (ΔU), frequency difference (Δf), and phase angle difference (Δφ) all fall within the preset limits.
    2. Voltage Check – When one side is energized and the other is not, this function verifies that the power flow direction is correct and the dead-time requirement is met, preventing load-side energization.
    3. Dual Circuit Breaker Scenario – With two completely independent stages (Stage 1/Stage 2) built in, it can monitor the closing conditions of two circuit breakers simultaneously, suitable for applications such as dual busbar systems, ring main units, or generator-transformer unit configurations.


    II. Key Parameter Ranges
    - Voltage difference ΔU: 2%…40% × Un (1% step)
    - Frequency difference Δf: 0.02…0.50 Hz (0.01 Hz step)
    - Phase angle difference Δφ: 5°…50° (1° step)
    - Slip cycle measurement threshold: >0.15 × Un for calculating Δf/Δφ
    - Deadband time (Voltage-check tVC): 0.1…20 s
    - Circuit breaker tripping time compensation tCB: 0…500 ms
    - Rated voltage input: 100 V or 110 V (50/60 Hz)
    - Auxiliary power supply: 80…265 V AC/DC or 18…80 V DC (Optional modules: SPFU 240R4 / SPFU 48R4)


    III. Hardware and Communication Interface
    - 19" 6U rack-mount enclosure, IP54 front panel; Weight ≈ 3 kg
    - 8 output relay contacts: 2× heavy-duty (CB closing pulse), 6× signal (start, trip, device fault)
    - Continuous hardware self-test: Internal fault <120 ms triggers IRF signal and locks output
    - Rear fiber optic SPA-BUS serial port (standard), compatible with ABB LonWorks/SCADA via SPA-ZC21/17 module; supports remote reading of real-time ΔU, Δf, Δφ values ​​and event logging


    IV. Typical Industry Applications
    - 6 kV power plant auxiliary busbar switching/tie-breaker
    - Hydro power plant generator output circuit breaker (GCB) synchronization
    - 220 kV substation double busbar switching operations
    - Oil platform ring main unit (DR) switchgear synchronization
    - SPACOM upgrade – SPAU 140 C and SPAU 341 C are directly interchangeable on the rail; only parameter settings need to be updated


    Product details pictures



    Related products


    SPAU 110 CSPAU 121 C
    SPAU 140 CSPAU 130 C
    SPAU 320 CSPAU 300 C
    SPAU 341 CSPAU 330 C
    SPAJ 140 CSPAF 140 C
    SPAJ 142 CSPAJ 141 C
    SPAJ 160 CSPAJ 144 C
    SPAC 315 CSPAM 150 C
    SPAC 320 CSPAC 317 C
    SPAD 346 CSPAS 120 C


    Quality SPAU 140 C ABB Synchro-check Relay Voltage-check Relay 50Hz 250V Ac/dc for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xiamen Changxuyuan Trading Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)